The A11J-S2 is a robust, modular UPS system offering power conditioning as well as up to 20kVA of redundant back-up power on demand.
Today’s companies are ever more dependent on microprocessors, computers, programmable logic controllers and other dedicated circuitry and software for commercial business applications. Just one or two seconds of a power surge or outage may bring your business to a complete standstill for hours or possibly days. Business Week estimates that power surges cost $26 billion a year in lost time, equipment repair and replacement costs.
The A11J protects critical equipment by isolating them from the raw incoming utility power and can provide up to 20kVA back up power. The A11J-S2 is modular by design allowing for all major subsystems such as batteries, inverter, and transformer to be serviced or replaced while the UPS continues to provide power to target systems. Additionally, the A11J-S2 is a redundant array of UPS systems. In the event of UPS failure, the other units within the configuration will continue to supply the same amount of conditioned power until the affected unit is repaired or replaced providing for 7/24 uptime when required by the application.
Features
Double Conversion Online
The A11J-S2 protects critical equipment by isolating them from the raw incoming utility power. Converting AC power to DC and then back to AC, the electrical output from the UPS is a pure sine wave in both voltage and frequency, providing clean, conditioned, and stable electrical power.
Redundancy
Providing 7/24 uptime for the UPS system, the A11J-S2 is a redundant parallel array of UPS systems. In the event one of the UPS systems fails, the others within the group continue to provide the same amount of conditioned power, allowing for the defective unit to be repaired or replaced.
Maintainability
The A11J-S2 utilizes an integrated maintenance bypass switch, allowing for electrical power to continue to supply electrical power to target equipment while batteries, inverter, and transformer are serviced or replaced.
Wide Input Range
This feature protects connected equipment from electrical sags and spikes. The wide range input capability also keeps the UPS from switching to reserve battery power allowing the backup batteries to remain at full charge as well as reducing stress on target equipment and UPS.
Auto Health Check
The A11J-S2 systematically checks the UPS through the integrated CPU controller. The system checks status on battery charge, discharge and voltage states as well as internal UPS temperatures. If anomalies are detected the UPS provides an alert alarm for system maintenance to the end user.
Power Correction
Power Factor Correction eliminates distortion and harmonic currents that are harmful to sensitive electrical equipment. Eliminating this distortion removes the potential for equipment performance issues, increases overall target equipment reliability, and reduces system power consumption.
Reduced EMI
Designed with reduced EMI emissions in mind, the A11J-S2’s internal circuity design was developed utilizing an acoustic anechoic chamber to test and validate the system. These extra steps ensure the lowest electrical noise possible reducing electrical interference problems to surrounding sensitive equipment.
Thermal Management
An integrated thermal management system monitors the internal temperature of the A11J-S2. The system will adjust cooling fan speed rotation depending on thermal requirements. When not required, cooling fans throttle down, lowering system noise, increasing fan life and lowering power consumption.
Coating Protection
Within the A11J-S2 UPS, a protective chemical coating is applied to protect electronic circuit boards from harsh environments that may contain moisture and or chemical contaminants. The coating is electrically insulated and provides a barrier to contaminants such as dust, insects, and salt-spray.
SANUPS SOFTWARE is a Web-based automated 7/24 shutdown assistant. When installed on shutdown target computers, your mission-critical equipment can be safely powered down in the event of an extended power loss. This ensures system up-time, data integrity, and the ability to maintain business continuity. The application shutdown function even shuts down Microsoft office applications as well. Systems administrators will receive remote email notification during power events.
Up to 16 (Optional) heat and humidity sensors can be installed for enhanced environmental monitoring of the UPS systems, equipment racks as well as rooms.
Quality
For over 90 years Sanyo Denki has been developing products. The A11J-S2 utilizes top of the line internal components such as capacitors, transformers, and reactors. These components are assembled under a rigorous ISO9001 quality control procedures. The result is superior durability and the ability to offer a long-life production platform, all within a small form-factor.
A11J-S2
Cabinet Type
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
5kVA | A11J Parallel Online UPS 5000VA | A11J502SA002U | 200V | 200V | I/O Terminal block |
10kVA | A11J Parallel Online UPS 10000VA | A11J103SA002U | 200V | 200V | I/O Terminal block |
15kVA | A11J Parallel Online UPS 15000VA | A11J153SA002U | 200V | 200V | I/O Terminal block |
20kVA | A11J Parallel Online UPS 20000VA | A11J203SA002U | 200V | 200V | I/O Terminal block |