Offering three unique power modes, the E11A is a durable electrical power conditioning, scale-able backup power solution, ideal for use with medical applications.
There is a growing need for Uninterruptable Power Supplies in the medical industry for not only hospitals, but out-patient clinics, research laboratories, and medical data centers. Newer technologies in hardware and software require clean, conditioned electrical power for peak performance and operation. In many cases, this delicate and expensive medical equipment operates in older building infrastructure and or on an outdated overburdened commercial electrical power grid requiring the use of an Uninterruptible Power Supply (UPS).
The E11A is a “Hybrid” UPS, meaning it can automatically switch between three different operational modes. This design is best utilized in environments looking to reduce power consumption expenses, as well as provide power protection for temporary power events or power loss.
Features
Hybrid / Three Modes
The E11A offers three power modes and will automatically switch depending on incoming power conditions. When no power issues are detected the system will operate in Economy mode that reduces power consumption and overall operating costs.
Scalable Power
With provisions for expandability the E11A can support up to 3kVA of backup electrical power and with additional external battery modules, backup time can be increased depending on system uptime requirements.
Wide Input Range
This feature protects connected equipment from electrical sags and spikes. The wide range input capability also keeps the UPS from switching to reserve battery power allowing the backup batteries to remain at full charge as well as reducing stress on target equipment and UPS.
Auto Health Check
The E11A systematically checks the UPS through the integrated CPU controller. The system checks status on a battery charge, discharge and voltage states as well as internal UPS temperatures. If anomalies are detected the UPS provides an alert alarm for system maintenance to the end user.
Power Correction
Power Factor Correction eliminates distortion and harmonic currents that are harmful to sensitive electrical equipment. Eliminating this distortion removes the potential for equipment performance issues, increases overall target equipment reliability, and reduces system power consumption.
Reduced EMI
Designed with reduced EMI emissions in mind, the E11A’s internal circuity design was developed utilizing an acoustic anechoic chamber to test and validate the system. These extra steps ensure the lowest electrical noise possible reducing electrical interference problems to surrounding sensitive equipment.
Leak Proof Battery
The E11A uses small-sized valve-regulated lead-acid (VRLA) batteries. The battery, sealed in a resin tray is double wall sealed helping to protect the UPS as well as equipment around the UPS as well as maintenance personnel.
Acoustic Noise Reduction
The E11A utilizes an internal thermal management system to reduce the audible noise coming from the UPS. This management system adjusts the cooling fan rotational speed depending on thermal requirements at that time. This built-in intelligence reduces the decibel levels generated by the UPS considerably.
Remote Management
With the optional LAN management card and SANUPS SOFTWARE, the E11A can provide for remote monitoring of the UPS as well as a shutdown assistant for medical equipment powered by the UPS.
SANUPS SOFTWARE is a Web-based automated 7/24 shutdown assistant. When installed on shutdown target computers, your mission-critical equipment can be safely powered down in the event of an extended power loss. This ensures system up-time, data integrity, and the ability to maintain business continuity. The application shutdown function even shuts down Microsoft office applications as well. Systems administrators will receive remote email notification during power events.
Up to 16 (Optional) heat and humidity sensors can be installed for enhanced environmental monitoring of the UPS systems, equipment racks as well as rooms.
Advanced Design & Components
For over 90 years Sanyo Denki has been developing products. The E11A utilizes top of the line internal components such as capacitors, transformers, and reactors. These components are assembled under a rigorous ISO9001 quality control procedures. The result is superior durability and the ability to offer a long-life production platform, all within a small form-factor.
E11A
Rack 120V Fixed
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 120V | E11A102B001USP | 120V | 120V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 120V | E11A152B001USP | 120V | 120V | NEMA 5-15P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 120V | E11A202B001USP | 120V | 120V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 120V | E11A302B001USP | 120V | 120V | NEMA L5-30P |
Rack 120V Fixed with EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 120V with EPO | E11A102B011USP | 120V | 120V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 120V with EPO | E11A152B011USP | 120V | 120V | NEMA 5-15P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 120V with EPO | E11A202B011USP | 120V | 120V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 120V with EPO | E11A302B011USP | 120V | 120V | NEMA L5-30P |
Rack 100/110/115/120V
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 100/110/115/120V | E11A102B001UJP(J) | 100V | 100V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 100/110/115/120V | E11A152B001UJPJ | 100V | 100V | NEMA 5-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 100/110/115/120V | E11A202B001UJP(J) | 100V | 100V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 100/110/115/120V | E11A302B001UJP(J) | 100V | 100V | NEMA L5-30P |
Rack 100/110/115/120V With EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 100/110/115/120V With EPO | E11A102B011UJPJ | 100V | 100V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 100/110/115/120V With EPO | E11A152B011UJPJ | 100V | 100V | NEMA 5-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 100/110/115/120V With EPO | E11A202B011UJPJ | 100V | 100V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 100/110/115/120V With EPO | E11A302B011UJPJ | 100V | 100V | NEMA L5-30P |
Rack 208V Fixed
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 208V | E11A102B002USP | 208V | 208V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 208V | E11A202B002USP | 208V | 208V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 208V | E11A302B002USP | 208V | 208V | NEMA L6-20P |
Rack 208V Fixed with EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 208V with EPO | E11A102B012USP | 208V | 208V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 208V with EPO | E11A202B012USP | 208V | 208V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 208V with EPO | E11A302B012USP | 208V | 208V | NEMA L6-20P |
Rack 200/220/230/240V
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 200/220/230/240V | E11A102B002UJP(J) | 200V | 200V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 200/220/230/240V | E11A202B002UJP(J) | 200V | 200V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 200/220/230/240V | E11A302B002UJP(J) | 200V | 200V | IEC60320-C20 |
Rack 200/220/230/240V With EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 200/220/230/240V with EPOw | E11A102B012UJP(J) | 200V | 200V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 200/220/230/240V with EPO | E11A202B012UJP(J) | 200V | 200V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 200/220/230/240V with EPO | E11A302B012UJP(J) | 200V | 200V | IEC60320-C20 |
Battery
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | External Battery Module For A11H/E11A (1kVA/ 20min up to x3)w | BCE11A102A01US | |||
1kVA | External Battery Module For A11H/E11A (1kVA/ 30min up to x2) | BCE11A102A02US | |||
1.5kVA | External Battery Module For A11H/E11A (1.5kVA/ 20min up to x3) | BCE11A152A01US | |||
1.5kVA | External Battery Module For A11H/E11A (1.5kVA/ 30min up to x2) | BCE11A152A02US | |||
2kVA | External Battery Module For A11H/E11A (2kVA/ 20min up to x3) | BCE11A202A01US | |||
2kVA | External Battery Module For A11H/E11A (2kVA/ 30min up to x2) | BCE11A202A02US | |||
3kVA | External Battery Module For A11H/E11A (3kVA/ 15min up to x3) | BCE11A302A03US | |||
3kVA | External Battery Modules For E11A 3kVA 208V (20min) | BCE11A302A01US |
Options
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
All | Air Filter for E11A and A11H | FL001 | |||
All | A11H & E11A Rack Support Rail | RM030-US |