Product description

Benefits & Features of the SANUPS A11H 3kVA Tower UPS include:

  • 3kVA \ 3000VA \ 2100W
  • SANUPS A11H offers 3kVA, 3kVA and 3kVA backup power product configurations
  • Backup battery runtime: 19 min @ 100%, 47 min @ 50% power draw
  • 3kVA Double conversion UPS topology for advanced power conditioning capabilities
  • 3kVA Tower UPS configuration (rack or tower options available)
  • Single Phase 120V 50/60hz input voltage
  • Wide Range AC power input capable
  • “Cold Start” capable
  • Input Power Factor Correction and pure sine wave output in both voltage and frequency
  • RS-232 port for monitoring and control. Optional software for network management and allowing systems to gracefully shutdown before the UPS battery discharges, multiple operating systems are supported
  • Automated battery management & test
  • Hot swappable battery modules for zero downtime during battery replacement
  • Long life, revision controlled Commercial Off-The-Shelf (COTS) UPS
  • Ruggedized enhancements such as protective chemical coatings, components epoxied into place, and double sealed batteries
  • Agency Approved: FCC Part 15, Subpart B, Class C: UL1778 5th edition (E226092)
  • Industry leading Three-year Warranty

Power Protection provided by the SANUPS A11H 3kVA Tower Uninterruptible Power Supply:

  • Power problems such as electrical surges and sags
  • Total loss of electrical power or hard power “re-boots”
  • Unstable incoming power caused from outdated or faulty electrical wiring and or power distribution equipment
  • Harmonic interference from neighboring “high power draw” equipment
  • Severe weather events such as lighting storms, ice and snow storms and downed power lines
  • Unstable power generation from local utilities or on-site generation

Wide Power Input

The SANUPS A11H 3kVA Tower UPS offers support for incoming wide utility power input. This feature protects the UPS and connected equipment and data from adverse voltage conditions. This feature stabilizes surges and sags without the need of engaging the backup batteries of the UPS during the power event. This greatly reduces stress on connected critical equipment and extends the battery life of the UPS.

Double Conversion Topology

The SANUPS A11H 3kVA Tower UPS provides true online double conversion providing the ultimate in clean and stable electrical power.  Incoming AC power is fed to the systems rectifier converting it from AC to DC power. The converted DC power charges the battery and feeds power to the inverter for conversion back to AC power. The resulting “double converted” electrical power is pure sine waveform output providing near perfect electrical power for connected equipment.

To ensure 7/24 up time the double conversion UPS topology utilizes a static “bypass switch” within its circuity design. If the UPS detects a system failure within the UPS, audible alarms will sound as the bypass switch is engages. This routes power around the failed UPS and ensures critical load is still supplied to critical equipment.

In the event of total power loss, the UPS will power off the rectifier when the loss of power is detected. The UPS’ internal backup batteries will continue to supply power to the inverter. There is no transfer time as the transition to battery power is instantaneous. This feature provides true uninterruptible power to mission critical equipment.

Technical Specifications

More
Model

A11H302A111USTWP

Rated Power Capacity (Apparent/Active)

3.0kVA / 2.1kW

Power Consumption

370 W

Expected Product Life Time

7 years

Connection

RS232C, EPO, Output Line Control Port, Remote Port

Acoustic Noise

50 dB max.

Operating Temperature

0 to 40°C

Operating Humidity

20 to 90%

Operating Elevation

3000 m max.

Unit Size (HxWxD)

6.89×25.98×19.84in (175x660x504mm)

Unit Weight

178.57lbs (81kg)

Unit Shipping Size (HxWxD)

Contact us

Unit Shipping Weight

Contact us

Certification

FCC Part 15 Subpart B Class C
UL1778 5th edition (E226092)

Rated Voltage (Input)

120 V

Frequency Range

40 to 120 Hz

Input Connection

NEMA L5-30P

Cord Length

6 ft

Voltage Range

55 to 150V(Load40%) 68 to 150V(Load70%) 80 to 150V(Load100%)

Rated Voltage (Output)

120 V

Voltage Harmonic Distortion

3% max. (Linear load)
7% max. (Non-linear load)

Rated Frequency

50/60 Hz

Topology

True online double conversion

Wave Form Type

Pure sine wave

Output Connection

NEMAL5-30Rx1

Bypass

Built in

Number Of Phases/Wires

Single-phase 2-wire

Output Voltage Range

±2% max.

Overload Capacity

105% (200 ms)

Efficiency (Maximum%)

Contact us

Battery Type

Leak Proof Small-sized valve-regulated lead-acid (VRLA) battery

Included Battery Packs

3 pcs

Replacement Battery

BPE11A302A00-1 x1
BPE11A302A01-1 x2

Typical Recharge Time (100%)

12 Hours

Expected Battery Life

5 years

Run Time (Load 100%)

19 min

External Battery Module

NA

External Battery Module Size (HxWxD)

NA

External Battery Module Weight

NA

External Battery Module Shipping Size (HxWxD)

NA

External Battery Module Shipping Weight

NA

Whats in the box

Floor Fixation Plate x2
Instruction Manual x1
Network cable x1
Power Management Software disc (Stand Alone Free Version) x1
UPS
User Settings Guide x1

Estimated Run-Time

Battery Run Time Graph