Offering three unique power modes, the E11A is a durable electrical power conditioning, scale-able backup power solution, designed for use for any commercial application.
Today’s companies are ever more dependent on microprocessors, computers, programmable logic controllers and other dedicated circuitry and software for commercial business applications.  Just one or two seconds of a power surge or outage may bring your business to a complete standstill for hours or possibly days. Business Week estimates that power surges cost $26 billion a year in lost time, equipment repair and replacement costs.
This Hybrid UPS offers three operational modes: Economy, Active Filter, and Double Conversion modes. Â The E11A is best used in environments looking to reduce power consumption expenses, as well as provide power protection for temporary power events or power loss.
Features
Hybrid / Three Modes
The E11A offers three power modes and will automatically switch depending on incoming power conditions. When no power issues are detected the system will operate in Economy mode that reduces power consumption and overall operating costs.
Scalable Power
With provisions for expandability the E11A can support up to 3kVA of backup electrical power and with additional external battery modules, backup time can be increased depending on system uptime requirements.
Wide Input Range
This feature protects connected equipment from electrical sags and spikes. The wide range input capability also keeps the UPS from switching to reserve battery power allowing the backup batteries to remain at full charge as well as reducing stress on target equipment and UPS.
Auto Health Check
The E11A systematically checks the UPS through the integrated CPU controller. The system checks status on a battery charge, discharge and voltage states as well as internal UPS temperatures. If anomalies are detected the UPS provides an alert alarm for system maintenance to the end user.
Power Correction
Power Factor Correction eliminates distortion and harmonic currents that are harmful to sensitive electrical equipment.  Eliminating this distortion removes the potential for equipment performance issues, increases overall target equipment reliability, and reduces system power consumption.
Reduced EMI
Designed with reduced EMI emissions in mind, the E11A’s internal circuity design was developed utilizing an acoustic anechoic chamber to test and validate the system. These extra steps ensure the lowest electrical noise possible reducing electrical interference problems to surrounding sensitive equipment.
Leak Proof Battery
The E11A uses small-sized valve-regulated lead-acid (VRLA) batteries. The battery, sealed in a resin tray is double wall sealed helping to protect the UPS as well as equipment around the UPS as well as maintenance personnel.
Thermal Management
An integrated thermal management system monitors the internal temperature of the E11A. The system will adjust cooling fan speed rotation depending on thermal requirements. When not required, cooling fans throttle down, lowering system noise, increasing fan life and lowering power consumption.
Coating Protection
Within the E11A UPS, a protective chemical coating is applied to protect electronic circuit boards from harsh environments that may contain moisture and or chemical contaminants. The coating is electrically insulated and provides a barrier to contaminants such as dust, insects, and salt-spray.
SANUPS SOFTWARE is a Web-based automated 7/24 shutdown assistant. When installed on shutdown target computers, your mission-critical equipment can be safely powered down in the event of an extended power loss. This ensures system up-time, data integrity, and the ability to maintain business continuity. The application shutdown function even shuts down Microsoft office applications as well. Systems administrators will receive remote email notification during power events.
Up to 16 (Optional) heat and humidity sensors can be installed for enhanced environmental monitoring of the UPS systems, equipment racks as well as rooms.
Quality
For over 90 years Sanyo Denki has been developing products. The E11A utilizes top of the line internal components such as capacitors, transformers, and reactors. These components are assembled under a rigorous ISO9001 quality control procedures. The result is superior durability and the ability to offer a long-life production platform, all within a small form-factor.
E11A
Rack 120V Fixed
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 120V | E11A102B001USP | 120V | 120V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 120V | E11A152B001USP | 120V | 120V | NEMA 5-15P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 120V | E11A202B001USP | 120V | 120V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 120V | E11A302B001USP | 120V | 120V | NEMA L5-30P |
Rack 120V Fixed with EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 120V with EPO | E11A102B011USP | 120V | 120V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 120V with EPO | E11A152B011USP | 120V | 120V | NEMA 5-15P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 120V with EPO | E11A202B011USP | 120V | 120V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 120V with EPO | E11A302B011USP | 120V | 120V | NEMA L5-30P |
Rack 100/110/115/120V
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 100/110/115/120V | E11A102B001UJP(J) | 100V | 100V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 100/110/115/120V | E11A152B001UJPJ | 100V | 100V | NEMA 5-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 100/110/115/120V | E11A202B001UJP(J) | 100V | 100V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 100/110/115/120V | E11A302B001UJP(J) | 100V | 100V | NEMA L5-30P |
Rack 100/110/115/120V With EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 100/110/115/120V With EPO | E11A102B011UJPJ | 100V | 100V | NEMA 5-15P |
1.5kVA | E11A Hybrid Online UPS Rack 1500VA 100/110/115/120V With EPO | E11A152B011UJPJ | 100V | 100V | NEMA 5-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 100/110/115/120V With EPO | E11A202B011UJPJ | 100V | 100V | NEMA L5-30P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 100/110/115/120V With EPO | E11A302B011UJPJ | 100V | 100V | NEMA L5-30P |
Rack 208V Fixed
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 208V | E11A102B002USP | 208V | 208V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 208V | E11A202B002USP | 208V | 208V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 208V | E11A302B002USP | 208V | 208V | NEMA L6-20P |
Rack 208V Fixed with EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 208V with EPO | E11A102B012USP | 208V | 208V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 208V with EPO | E11A202B012USP | 208V | 208V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 208V with EPO | E11A302B012USP | 208V | 208V | NEMA L6-20P |
Rack 200/220/230/240V
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 200/220/230/240V | E11A102B002UJP(J) | 200V | 200V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 200/220/230/240V | E11A202B002UJP(J) | 200V | 200V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 200/220/230/240V | E11A302B002UJP(J) | 200V | 200V | IEC60320-C20 |
Rack 200/220/230/240V With EPO
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | E11A Hybrid Online UPS Rack 1000VA 200/220/230/240V with EPOw | E11A102B012UJP(J) | 200V | 200V | NEMA L6-20P |
2kVA | E11A Hybrid Online UPS Rack 2000VA 200/220/230/240V with EPO | E11A202B012UJP(J) | 200V | 200V | NEMA L6-20P |
3kVA | E11A Hybrid Online UPS Rack 3000VA 200/220/230/240V with EPO | E11A302B012UJP(J) | 200V | 200V | IEC60320-C20 |
Battery
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
1kVA | External Battery Module For A11H/E11A (1kVA/ 20min up to x3)w | BCE11A102A01US | |||
1kVA | External Battery Module For A11H/E11A (1kVA/ 30min up to x2) | BCE11A102A02US | |||
1.5kVA | External Battery Module For A11H/E11A (1.5kVA/ 20min up to x3) | BCE11A152A01US | |||
1.5kVA | External Battery Module For A11H/E11A (1.5kVA/ 30min up to x2) | BCE11A152A02US | |||
2kVA | External Battery Module For A11H/E11A (2kVA/ 20min up to x3) | BCE11A202A01US | |||
2kVA | External Battery Module For A11H/E11A (2kVA/ 30min up to x2) | BCE11A202A02US | |||
3kVA | External Battery Module For A11H/E11A (3kVA/ 15min up to x3) | BCE11A302A03US | |||
3kVA | External Battery Modules For E11A 3kVA 208V (20min) | BCE11A302A01US |
Options
Capacity | Product Name | Part Number | Input | Output | Input Connection |
---|---|---|---|---|---|
All | Air Filter for E11A and A11H | FL001 | |||
All | A11H & E11A Rack Support Rail | RM030-US |